£20.43
On Hold
AC/DC LED Regulated Switching Power Supply S-100-48,48VDC Output,96W
More than 10 available
Details
Shipping: United Kingdom: free (more destinations)
Condition: Brand new
*The store has not been updated recently. You may want to contact the merchant to confirm the availability of the product.
AC/DC LED Regulated Switching Power Supply S-100-48,48VDC Output,96W
Features:
High efficiency, high reliability
Universal AC input / Full range
100% full load burn-in test
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
DC Output Voltage: 48VDC;
Output Voltage Tolerace: +/-1%;
Output Current: Amps 2;
Output Current Range: 0~2Amps;
Output Power: 96Watts;
Ripple And Noise: 150mvp-p;
Voltage Range: +/-10%;
Input Voltage Range: 85~132VAC/180~264VAC,
255~373VDC;
Frequency: 47~63Hz;
AC Input Current:2.4A/115V,1.2A/230V;
Efficiency: 83%;
AC Inrush Current: Cold-Start Current:
18A/115V,36A/230V;
Working Temperature And Humidity: -10 Degree C~+60Degree C, (refer to output rating curve )20%~90% RH;
Storage temperature and humidity: -20 Degree C~+85 Degree C, 10%~95% RH;
Leakage Current: <3.5 mA/240VAC;Setup,Rise,Hold Time: 200ms,80ms,20ms at full load ;
Vibration : 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes ;
SAFETY Withstand Voltage : I/P-O/P:1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC ;Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG100M Ohms/500VDC ;STANDARD ;
Safety Standard: Design refer to UL1012 ;EMC Standard : Design refer to FCC Part15 J Conduction Class B;
Standards: CE
Features:
High efficiency, high reliability
Universal AC input / Full range
100% full load burn-in test
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
DC Output Voltage: 48VDC;
Output Voltage Tolerace: +/-1%;
Output Current: Amps 2;
Output Current Range: 0~2Amps;
Output Power: 96Watts;
Ripple And Noise: 150mvp-p;
Voltage Range: +/-10%;
Input Voltage Range: 85~132VAC/180~264VAC,
255~373VDC;
Frequency: 47~63Hz;
AC Input Current:2.4A/115V,1.2A/230V;
Efficiency: 83%;
AC Inrush Current: Cold-Start Current:
18A/115V,36A/230V;
Working Temperature And Humidity: -10 Degree C~+60Degree C, (refer to output rating curve )20%~90% RH;
Storage temperature and humidity: -20 Degree C~+85 Degree C, 10%~95% RH;
Leakage Current: <3.5 mA/240VAC;Setup,Rise,Hold Time: 200ms,80ms,20ms at full load ;
Vibration : 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes ;
SAFETY Withstand Voltage : I/P-O/P:1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC ;Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG100M Ohms/500VDC ;STANDARD ;
Safety Standard: Design refer to UL1012 ;EMC Standard : Design refer to FCC Part15 J Conduction Class B;
Standards: CE