£82.56
Add to Cart
Vintage Soviet Russian Ussr Combined Electrical Analogue Instrument 43102
There is a hairline crack in glass panel. You can see in photo.It does not effect performance. Meter is still under factory seal.Vintage Soviet Russian Ussr Combined Electrical Analogue Instrument 43102 is designed to measure DC voltage, rms AC voltage sine wave, DC resistance, speed of the crankshaft of the engine, including engines with non-contact ignition system, and the angle of the closed state of the breaker contacts four-, six-and eight-cylinder engines with electric 12V and negative polarity of the "masses".Specifications: Electrical appliances combined analog devices 43102:The limits of the scale (initial and final values of the measuring range) limits. Allowed values of the basic errors of the device in normal conditions of use (Table 2), the values of current consumption device correspond to the values specified in Table 1;Table 1: Values of the combined unit of consumed electrical analog device current 43102MeasurandMeasuring range (initial and final value)Maximum permissible inaccuracyConsumption of no more thanDirect current voltage0V-2V, 0V-20V, 0V-40V± 1,5%0.105 mAAC voltage60V-400V± 2,5%0.510 mADC Resistance0 k = 0, 1 k, 0 k, 100 k± 2,5%0.16 mARotational speed of the engine crankshaft0min 1500min -1, -1, -1 0min-9000min -1± 2,5%15mAThe angle of the closed state of the breaker contacts0 º -45 º, 0 º -60 º, 0 º -90 º± 2,5%15mATable 2 Limits. Allowed values of the basic errors of the combined unit of electrical analogue instrument 43102 in normal conditions of useInfluence quantityAverage value (range)AMBIENT TEMPERATURE20 º C ± 5 º CRegulationsHorizontal ± 2 ºThe orientation of the device (relative to Earth's magnetic field)anyAn external magnetic fieldGeomagnetic fieldAn external electric fieldThe virtual absence ofRelative air humidity :30% -80%Atmospheric pressure84kPa-106, 7kPa (630mm.rt.st.-802mm.rt.st.)Frequency of measured voltage45Hz-65HzThe shape of the measured ACSinusoidal with THD less than 2%Power supply circuit ohmmeter1.35 In-1 65VThe power supply voltage measuring circuit speed of the engine crankshaft and the angle of the closed state of the breaker contacts10.8 V-15, 0VFerromagnetic ground-The coefficient of the variable component of the DC voltageno more than 3%The limits of acceptable basic and additional errors in the combined unit of electrical analogue instrument 43102 expressed in the form of error given by the formula:γ = ± ((100 ∙ Δ) / X)where Δ - the absolute error, X - normalizing value.Normalizing values are given in determining the errors are:- When measuring DC and AC current, frequency, engine speed and the angle of the closed state of the breaker contacts - a finite value of the measurement range;- When measuring the DC resistance - the entire length of the scale, with a minimum of:- 46mm - for measuring range 0 k, 100 k;- 54mm - for measuring range 0 MW-100 MW;The limits of permissible values of the combined instrument additional errors electrical analogue instrument 43102 due to the slope of the device by 10 ° in any direction from the changes of ambient temperature for each 10 ° C does not exceed the limit of acceptable basic error;Will be shipped from Europe by Air Mail International priority mail.Thanks for lookingI will ship to Worldwide. PayPalor Paypal eCheck. Same flat shipping rate to worldwide as to US Mainland. If not clear about shipping price, please ask to calculte..





LT, Vilnius