£67.55
Add to Cart
LOWERING VALVE FOR ANTHONY LIFTGATES
More than 10 available
Details
Shipping: United Kingdom: £27.00 (more destinations)
Condition: Brand new
223758, LH121, LH00094L, 4445 , 70092503, 4423680, 442227
Lowering Valve for Anthony Liftgates
•Conventional (AC) Series
•Railtrac Series
•Tuckunder
Troubleshooter from Anthony Liftgates Website
Action -Liftgate not lowering
Check all connections and all connectors for worn, loose, or corroded connections. Replace any defective terminals with 'heat shrink' factory terminal.
Part Numbers -
N/A
Possible Cause #2
Bad lowering valve coil.
Action -
Remove coil from lowering cartridge and test magnetism of inside of coil with metal object ( i.e. screwdriver ) while energizing 'down' control side of switch only.
Part Numbers -
ATU-121 (Monarch Lowering Valve)
ATU-479 (Fenner Lowering Valve)
Possible Cause #3
Latch assembly not unlatched.
Action -
With platform on ground, remove lowering valve and inspect. Clean if dirty. Replace if plunger not freely moveable
Part Numbers -
ATU-121 (Monarch lowering valve)
ATU-479 (Fenner lowering valve)
Possible Cause #4
Latch assembly not unlatched.
Action -
Unlatch assembly.
Part Numbers -
ATU-195 (Latch Assembly)
Replaces part #
•ATU121 Anthony
•Maxon 223758
•Leyman LH121
•Leyman LH00094L
•Thieman 4445
•Waltco 70092503
•Thieman 4423680
•Thieman 4422270
•Del America 16403
BMF3330
•
Cross Reference:
ATU121 Anthony•Maxon 223758
•Leyman LH121
•Leyman LH00094L
•Thieman 4445
•Waltco 70092503
•Thieman 4423680
•Thieman 4422270
•Del America 16403
Lowering Valve for Anthony Liftgates
•Conventional (AC) Series
•Railtrac Series
•Tuckunder
Troubleshooter from Anthony Liftgates Website
Action -Liftgate not lowering
Check all connections and all connectors for worn, loose, or corroded connections. Replace any defective terminals with 'heat shrink' factory terminal.
Part Numbers -
N/A
Possible Cause #2
Bad lowering valve coil.
Action -
Remove coil from lowering cartridge and test magnetism of inside of coil with metal object ( i.e. screwdriver ) while energizing 'down' control side of switch only.
Part Numbers -
ATU-121 (Monarch Lowering Valve)
ATU-479 (Fenner Lowering Valve)
Possible Cause #3
Latch assembly not unlatched.
Action -
With platform on ground, remove lowering valve and inspect. Clean if dirty. Replace if plunger not freely moveable
Part Numbers -
ATU-121 (Monarch lowering valve)
ATU-479 (Fenner lowering valve)
Possible Cause #4
Latch assembly not unlatched.
Action -
Unlatch assembly.
Part Numbers -
ATU-195 (Latch Assembly)
Replaces part #
•ATU121 Anthony
•Maxon 223758
•Leyman LH121
•Leyman LH00094L
•Thieman 4445
•Waltco 70092503
•Thieman 4423680
•Thieman 4422270
•Del America 16403
BMF3330
•
Cross Reference:
ATU121 Anthony•Maxon 223758
•Leyman LH121
•Leyman LH00094L
•Thieman 4445
•Waltco 70092503
•Thieman 4423680
•Thieman 4422270
•Del America 16403